FAST HIGH VOLTAGE SOLID-STATE SWITCHES |
|
C3 |
HV switch, variable on-time, low capacitance, MOSFET |
|
● Versatile HV switch with true relay character ● On-time controllable by TTL signal ● Simplified EMC and reduced capacitive losses due to low coupling capacitance ● Now available: LC2 technology for highest transient immunity
Note: The model number contains coded information about voltage, current and turn-on behavior. The first digits stand for the voltage in kV, the last digit before the dash indicates the turn-on behavior (0 = fixed on-time, 1 = variable on-time). The digits after the dash indicate the current in Amperes x10. Special features are coded by the letters after a second dash. Example HTS 31-12-LC: HTS = HV Transistor Switch, 3 = 3 kV, 1 = variable on-time, 12 = 120 Ampere, LC = Low Capacitance.
|
|
Model [sorted by |
Description / Comment |
Dimensions |
Voltage |
Pk. Current |
On-Resist. |
On-Time |
|
| HTS 31-12-LC | ● |
89 x 64 x 27
|
3
|
120
|
1.25
|
60…∞
|
|
| HTS 61-06-LC | ● |
89 x 64 x 27
|
6
|
60
|
5
|
60…∞
|
|
| HTS 111-03-LC | ● |
89 x 64 x 27
|
11
|
30
|
24
|
60…∞
|
|
| HTS 121-03-LC | ○ |
89 x 64 x 27
|
12
|
30
|
24
|
60…∞
|
|
| HTS 41-12-LC | ● |
112 x 64 x 27
|
4.5
|
120
|
2.5
|
60…∞
|
|
| HTS 91-06-LC | ● |
112 x 64 x 27
|
9
|
60
|
10
|
60…∞
|
|
| HTS 161-03-LC | ● |
112 x 64 x 27
|
16
|
30
|
36
|
60…∞
|
|
| HTS 181-03-LC | ○ |
112 x 64 x 27
|
18
|
30
|
36
|
60…∞
|
|
| HTS 81-12-LC | ○ |
200 x 70 x 27
|
8
|
120
|
3.75
|
100…∞
|
|
| HTS 91-12-LC | ● |
200 x 70 x 27
|
9
|
120
|
3.75
|
100…∞
|
|
| HTS 161-06-LC | ○ |
200 x 70 x 27
|
16
|
60
|
15
|
100…∞
|
|
| HTS 181-06-LC | ● |
200 x 70 x 27
|
18
|
60
|
15
|
100…∞
|
|
| HTS 331-03-LC | ● |
200 x 70 x 35
|
33
|
30
|
72
|
100…∞
|
|
| HTS 361-03-LC | ○ |
200 x 70 x 35
|
36
|
30
|
72
|
100…∞
|
|
| HTS 161-12-LC | ○ |
263 x 70 x 35
|
16
|
120
|
7.5
|
150…∞
|
|
| HTS 181-12-LC | ● |
263 x 70 x 35
|
18
|
120
|
7.5
|
150…∞
|
|
| HTS 331-06-LC | ○ |
263 x 70 x 35
|
33
|
60
|
30
|
150…∞
|
|
| HTS 361-06-LC | ● |
263 x 70 x 35
|
36
|
60
|
30
|
150…∞
|
|
| HTS 121-20-LC2 | ● |
103 x 70 x 35
|
12
|
200
|
1.95
|
120…∞
|
|
| HTS 201-10-LC2 | ● |
103 x 70 x 35
|
20
|
100
|
7.8
|
120…∞
|
|
| HTS 501-10-LC2 | ● |
252 x 150 x 68
|
50
|
100
|
18
|
250…∞
|
|
| HTS 501-20-LC2 | ● |
252 x 200 x 68
|
50
|
200
|
9
|
250…∞
|
|
| HTS 501-40-LC2 | ● |
372 x 150 x 68
|
50
|
400
|
4.5
|
250…∞
|
|
| HTS 501-80-LC2 | ● |
372 x 300 x 68
|
50 | 800 | 2.25 | 250…∞ | |
| HTS 701-10-LC2 | ● |
312 x 150 x 68
|
70
|
100
|
25
|
250…∞
|
|
| HTS 701-20-LC2 | ● |
312 x 200 x 68
|
70
|
200
|
12.5
|
250…∞
|
|
| HTS 901-10-LC2 | ● |
372 x 150 x 68
|
90
|
100
|
32
|
250…∞
|
|
| HTS 901-20-LC2 | ● |
372 x 200 x 68
|
90
|
200
|
16
|
250…∞
|
|
| HTS 1001-10-LC2 | ● |
432 x 150 x 68
|
100
|
100
|
36
|
250…∞
|
|
| HTS 1001-20-LC2 | ● |
432 x 200 x 68
|
100
|
200
|
18
|
250…∞
|
|
| HTS 1001-40-LC2 | ● |
372 x 150 x 130
|
100
|
400
|
9
|
250…∞
|
|
| HTS 1001-80-LC2 | ● |
372 x 300 x 130
|
100
|
800
|
4.5
|
250…∞
|
|
| HTS 1201-10-LC2 | ● |
492 x 150 x 68
|
120
|
100
|
42
|
250…∞
|
|
| HTS 1201-20-LC2 | ● |
492 x 200 x 68
|
120
|
200
|
21
|
250…∞
|
|
| HTS 1401-10-LC2 | ● |
672 x 150 x 68
|
140
|
100
|
52
|
250…∞
|
|
| HTS 1401-20-LC2 | ● |
672 x 200 x 68
|
140
|
200
|
26
|
250…∞
|
|
| Old models | Switches are available, but not recommended for new development: | ||||||
| HTS 501-03-LC | X | Use HTS 501-10-LC2 for new development |
260 x 70 x 35
|
50
|
30
|
86
|
150…∞
|
| HTS 651-03-LC | X | Use HTS 701-10-LC2 for new development |
300 x 70 x 35
|
65
|
30
|
144
|
150…∞
|
| HTS 721-03-LC | X | Use HTS 701-10-LC2 for new development |
300 x 70 x 35
|
72
|
30
|
144
|
150…∞
|
|
Options (1) |
|
|
|
|
|
HFB |
High Frequency Burst: Improved burst capability of driver by means of external buffer capacitors. Recommended if more than 10 pulses with less than 10 μs spacing are generated. |
|
HFS |
High Frequency Switching: External supply of auxiliary driver voltage (50-350 VDC according to type). Necessary if the specified “Maximum Operating Frequency” shall be exceeded. (2) |
|
LP |
Low Pass: Low pass filter at the control input. Propagation delay time will be increased by ~50 ns. Jitter + 500 ps. Improved noise immunity and less critical wiring in high speed applications. (3) |
|
MIN-ON |
Minimum On-Time: Individually increased Minimum On-Time to ensure a minimum on duration indepently of control signal. For safety relevant circuits. |
|
MIN-OFF |
Minimum Off-Time: Individually increased Minimum Off-Time to ensure a minimum off duration indepently of control signal. For safety relevant circuits. |
|
LL |
Low Leakage Current: Off-state current reduced to less than 10% of the specified value. Not available in connection with the cooling fin options and for switches of the UF series. |
|
LN |
Low Noise: Internal power driver modified for zero noise emission for a specific period of time. Relevant in conjunction with sensitive detector amplifiers (e.g. SEV/MCP applications) only. (2) |
|
ISO-25 |
25 kV Isolation: Isolation Voltage increased to 25 kVDC. Housing dimensions may change for some models. |
|
ISO-40 |
40 kV Isolation: Isolation Voltage increased to 40 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
|
ISO-80 |
80 kV Isolation: Isolation Voltage increased to 80 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
|
ISO-120 |
120 kV Isolation: Isolation Voltage increased to 120 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
|
ISO-200 |
200 kV Isolation: Isolation Voltage increased to 200 kVDC. Housing dimensions may change for some models. Only in connection with option PT-HV. |
|
I-PC |
Integrated Part Components: Integration of small part components according to customer’s specifications (e.g. buffer capacitors, snubbers, damping resistors, diodes, opto couplers). (2) |
|
I-FWD |
Integrated Free-Wheeling Diode: Built-in parallel diode with short recovery time. In connection with inductive load only. |
|
I-FWDN |
Integrated Free-Wheeling Diode Network: Built-in parallel diode plus serial blocking diode with short recovery time. In connection with inductive load only. |
|
LS-C |
LEMO socket for Control Connection. Input ipedance 100Ω. An assenbled linkage cable (1m/3ft) with two plugs plus one additional socket is included in supply. Improved noise immunity. (3) |
|
PT-C |
Pigtail for Control Connection: Flexible leads (l=75 mm) with PCB connector. This option is only relevant for switching modules with pins. Recommended for modules with options CF & GCF. |
|
PT-HV |
Pigtails for HV Connection: Flexible leads with cable lugs. For increased creepage. PT-HV is standard for all types with >25 kV switching voltage. Not recommended in extremely fast circuits. |
|
ST-HV |
Screw Terminals for HV Connection: Threaded inserts at the bottom of module (if not standard). For PCB design. Operation above 25 kV requires liquid insulation (Galden®/Oil) or potting. |
|
SEP-C |
Separated Control Unit. Control unit with LED indicators in a separate housing (dim. 79x38x17 mm). Linkage cable (<1m) with plug. Control unit with soldering pins or pigtails. |
|
UL94 |
Flame Retardant Casting Resin: Casting resin according to UL-94-VO. Minimum order quantity required. (2) |
|
TH |
Tubular Housing: Tubular instead of rectangular housing. Adaption to specific ambient conditions or in case of difficult assembly situations. (2) |
|
FC |
Flat Case: Height of standard plastic housings reduced to 19 mm or less. Not in combination with cooling options CF, GCF and DLC. |
|
ITC |
Increased Thermal Conductivity: Special moulding process to increase the thermal conductivity of the module. Pd(max) will be increased by approx. 20-30%. (2) |
|
CF |
Non-Isolated Cooling Fins: Standard sizes in categories I to VII according to model. Nickel plated copper 0.5 mm, fin height 35 mm. For air and liquid cooling (e.g. Galden® or oil). |
|
CF-1 |
Non-Isolated Cooling Fins d=1mm: Nickel plated copper 1.0 mm instead of 0.5 mm. The Max. Power Dissipation will be increased by ~80 %. For air and liquid cooling (e.g. Galden® or oil). |
|
CF-X2 |
Non-Isolated Cooling Fins enlarged by x2: Fin area enlarged by factor 2. Not relevant in connection with liquid cooling. |
|
CF-CS |
Non-Isolated Cooling Fins with customized shape: Individual shape to meet specific OEM requirements. (2) |
|
CF-GRA |
Non-isolated Cooling Fins made of graphite. Very light weight compared to copper at similar heat transfer, but reduced heat capacity. 0.5 or 1 mm thickness, height 35 mm. |
|
CF-CER |
Isolated Cooling Fins made of ceramics. Heat transfer properties similar to alumina. Forced convection recommended, height 35 mm. |
|
CCS |
Ceramic Cooling Surface. Top side of switching module made of special ceramics. Heat transfer properties similar to alumina. Forced convection recommended. |
|
C-DR |
Cooling for Driver: Extra cooling for the driver and control electronics. Recommended in combination with option HFS at higher switching frequencies. (2) |
|
GCF |
Grounded Cooling Flange: Nickel-plated copper flange for medium power. Max. isolation voltage 40kV. Increased coupling capacitance CC. |
|
ILC |
Indirect Liquid Cooling: Liquid cooling for all kind of conductive coolants incl. water. Internal heat exchanger made of ceramics. For medium power dissipation. |
|
DLC |
Direct Liquid Cooling: Internal cooling channels arround the power semiconductors. The most efficient cooling for high frequency applications. Non-conductive coolants only. |
|
HI-REL |
High Reliability / MIL Versions: Available on request. (2) |
|
|
|
|
(1) New option code: Data
sheets may differ from this coding system (especially older ones) and
do not indicate all possible options as per above table. (2) Please
consult factory for detailed information. |
|
|
|
|
|
Further information, data sheets and drawings are available on request. All data and specifications subject to change without notice. BEHLKE POWER ELECTRONICS 07-11-2011 |
|
![]() |